GFM 2.0

Direct Methane Leak Detection Detector


Design:

By utilizing a suitcase-style design, the user can conveniently carry the device using a special backpack. The durable materials and their quality have enabled the device to obtain ATEX certification. The lightweight construction, combined with the ability to carry the detector as a backpack, provides outstanding comfort and mobility in use.

Battery:

The use of the latest detector performance optimization systems has increased its operational efficiency, allowing up to 8 hours of continuous operation.

Technology:

Innovative technologies used in the detector enable rapid measurement of both small and large gas leaks. Detection is carried out by drawing in air into the device, where infrared optical sensors instantly provide information about the gas concentration. The device can intake up to 350 L/min of air while maintaining excellent reading precision.

Functionality:

The device is designed to operate even in the most challenging conditions. Thanks to the technology used, leak detection is possible even at -20°C. The carrying method ensures comfort and safety by freeing the user’s hands from holding the detector. This solution allows the user to move freely, for example, when climbing a ladder.

Easy to use:

GFM 2.0 allows real-time data reading from an Android device. This solution makes using the device incredibly intuitive and fast.


Technical parameters:
Display:TFT Display
Buttons:On/Off
Connection:Bluetooth, USB
Software:Android
Standard data:Sample flow rate
Background concentration
Measured gas concentration
Battery status
Measured values:Leak size calculated based on the sample flow rate, gas sample concentration measurement, and background concentration measurement.
Measured leak value:from 0.28 to 350.0 l/min; from 0.01 to 14.2 kg/hr
Min. leak value:0.22 l/min; 0.009 kg/hr
Leak measurement deviation:+/- 5% of reading
Temperatures:
 
Humidity:
Operating: from -20°C up to 50°C
Storage: from -40°C up to 60°C
5 do 95% RH (without condensation)
Flow:Max: 350 l/min; 14.2 kg/hr
Medium: 250 l/min; 10.2 kg/hr
Low: 150l/min; 6.10 kg/hr
Flow measurement method:Pressure drop across the Venturi constriction
Methane sensor:Optical NDIR
Range from 0 up to 100% methane
Accuracy +/- 5% of reading or 0.1% of methane
Oxygen sensor:Electrochemical O₂ sensor with an auto-correction function.
Battery:Type:explosion-proof , low-heating LiPo 3.7V
Memory:Last 50h of operation
Dimensions:29cm x 28.5cm x 10cm
Wight:4.2 kg
Certificates:UL Class I, Div 2, CE Atex