JBS-600 Control Unit


  • Capability to manage up to 32 sensors.
  • 4″ display enabling continuous monitoring of alarm status and gas concentrations sent from the sensor in real time.
  • Simple and intuitive method of navigating the software via touch screen or navigation keypad.
  • Compatible with many types of sensors, such as NET-Ex, C3-NET, or JBS-410.
  • Controller equipped with up to 16 relay outputs. Each of them can be assigned to one or more events (e.g., alarm threshold exceeded, detector malfunction).
  • Communication with external devices (e.g., signals, fans).
  • Normal and service modes can be configured separately for each sensor.
  • Discrete programmable alarm channels, from 3 in the standard version to 9 in the most advanced version.
  • Controller status viewable via web browser
  • The device can operate as Modbus RTU and Modbus TCP. An RJ45 connector is provided for this purpose.
  • Wide range of custom designs available on request.

Description:

The JBS-600 controller offers maximum functionality thanks to the possibility of installing up to 32 sensors and the ability to continuously monitor and manage their status via a built-in touchscreen display. The use of Mobus RTU and Mobus TCP networks allows for constant remote control of detailed information such as errors, gas concentrations of each sensor, alarms, and historical data. The JBS-600 has external device management functions using up to 16 relay outputs.

The user can program each sensor independently. Setting alarm thresholds and related actions is available to the user from the touch panel. When an alarm occurs, operators and employees are notified, and depending on the configuration, the controller performs the actions previously set for it at that time. Relay outputs can be freely programmed with navigation signals, horns, or fan controls.


Attention:

The system is primarily designed to work with existing, installed C3-NET or NET-EX series smart gas detectors. When designing and installing a new detection system, it is recommended to use NET-EX or C3-NET detectors equipped with Modbus digital outputs, connected to the MB, MC, or ASIX control system. Unlike the analog 4-20 mA signal, the digital Modbus signal is unmodifiable and non-repudiable, guaranteeing above-average information security.

Technical parameters:
Type:Control unit
Standard outputs:Modbus RTU and Modbus TCP
Optional outputs:8 ÷ 32 sensors with 4-20 mA
Display:Colorful display 4″ (480×320)
Alarm outlets:3 ÷ 9 depends on need
Power supply:24V DC max. 5A (directly or via 230V AC/24V DC power supply)
Digital outputs:Modbus RTU through RJ45

Modbus TCP through Ethernet
Permissible temperature / humidity:0°C – 40°C / 20% – 70% RH
Dimensions:79,75 x 225 x 174,8mm
Certificates:CE
ATEX:Not available (Note: ATEX available for NET-EX series sensors)